Clean Room Decorated Design Requirements

Shanghai Construction Decoration Engineering Co., Ltd. of your application, we are specialized in Shanghai Shanghai office decoration decoration factories, office buildings, the Shanghai plant decoration design and construction units.

Companies registered capital of San Bai million yuan, the National Building Decoration Engineering Design and Construction of three qualified units, the Shanghai Construction Decoration Industry Association member units, ISO9001 quality system certification. Since its inception, the company adhere to the “Quality is life, reputation is the development of the road, the service is the soul of competition,” development concept.

The company has excellent service team, customer service in the great concentration of business in the constantly developing, establishing a good corporate image and reputation, by the Shanghai Construction Decoration Industry Association as a “trust building decoration company in Shanghai.” Since its inception, insisted that “cooperation, development, progress, excellence” team spirit.

In practice, training and developed a group of senior engineering and technical personnel and management personnel to create a “excellent Sheji as soul, Pei Tao Bao Zheng construction overall, with excellent Shi Gong to achieve high,” the major management model, fuse Eastern and Western cultures, Yun Yong Shidailinian , advanced technology and materials, good service, creating delicate and humane of all Space. First-class work will be presented to the owners and service is the cornerstone of our continued development and pursuit.

A clean room of the building layout is usually in the factory sealed corridor outside the setting of a ring. It makes clean area with a buffer zone with the outside world. To prevent pollution of the outside world but also the relative energy. Factories within the doors and windows fit to the wall formation, does not set window. Layers outside the window settings and structure to take full account of the air moisture seal, so that pollution particles easily penetrate from the outside.

To prevent condensation caused by temperature difference between indoor and outdoor, indoor rooms with different cleanness gap between the doors and windows should be sealed. Window material should be selected with good weather, natural distortion, manufacturing error is small, airtight good shape should be simple, easy to dust, easy to clean, no door threshold. Clean room doors and windows of metal or metal coated material is preferred not to use wood windows and doors, to avoid long-term wet bacteria. Appropriate windows on the external walls and internal walls smooth, beveled window sill or not to stay, and for the double fixed windows to reduce energy loss.

2. easy to clean smooth surface applications.

Application of flat ground plant decoration, seamless, corrosion resistant, easy to gather static electricity, facilitate the overall ground clearance. Design can be used in place terrazzo floor, the use of stones in the 6-15mm in diameter should be between. One article must be separated by copper strips separated by not using the glass article. Ping is more epoxy surface gravity, which is a resin composites flooring.

It is characterized by solvent-free, non-toxic tasteless, seamless, gravity leveling. Can. Up mirror decorative, seamless, oil type and acid, alkali, salt, chemical solvents. With anti-static, dust and small hair, wear characteristics of impact resistance, but high cost. Most use in demanding cleanliness, beautiful appearance, clean, sterile electronics, medicine, blood products and other industry production shop floor. Epoxy floor surface gravity over the life of the thickness of 1mm is generally used for more than 6 years. Cushion above the ground floor should be laid under the vapor barrier, concrete sub-warehouse line not through the clean area.

3. wall should be smooth wall surface should be smooth, flat, dust resistant, color harmony, and ease of identification of pollutants, interior paint must be mold, anti-static, to avoid glare and can withstand cleaning and disinfection of the material brushing. The intersection of wall and floor to do a radius of 50 mm arc, in order to reduce dust build-up and easy to clean. Transport corridors and the wall should easily hit office setting bull bars, prevent vibration and dust off decorative materials.

4. air tube, lighting must be arranged in the technical dissection in order to ensure clean room clean room, all air pipes, lamps must be arranged in the technical dissection. Most pharmaceutical companies now use color steel sandwich panels sealed ceiling. Color steel sandwich panels with a light weight, the overall strength, good integrity, thermal insulation made of small dust characteristics, more suitable for GMP production plant.

However, the fixed suspended ceiling structure of the main body must be connected not with the equipment, pipeline support mix. Ceiling and wall surfaces should be smooth connection. Ceiling and return air duct mouth to be closed reliably. Ceiling lights after installation to conduct inspection, to ensure seamless. According to process requirements, the general should be set within the technical dissection repair walkways, easy to pipeline maintenance and replacement filters. Dissection of the wall and ceiling technology required to brush coating.

Author Bio: www.cheaponsale.com contain a great deal of information about bathroom pebble tile,designer car mats,bedroom door locks, welcome to visit!